Институт «Производство №1» — единый реестр расхождений и стоп-условий ТАТПРОФ / VIDNAL
Дата: 10.09.2026.
Назначение: обязательный preflight-слой перед калькулятором, автоспецификацией, закупкой и производственным допуском. P0 блокирует автоматический допуск; P1 требует проверки источника/редакции; P2 — организационное расхождение, которое нельзя терять при обновлении базы.
| ID | Производитель | Система | Приоритет | Риск / расхождение | Правило |
|---|---|---|---|---|---|
| TFS50-WEB-01 | TATPROF | TFS50 | P1 | web structural infill 4–70 mm vs catalog up to 72 mm | keep both by source/revision; do not auto-select a maximum |
| TFS50-AUTO-01 | TATPROF | TFS50 | P0 | structural sealant quantity formula has garbled H*/H** variables in extracted text | block calculator formula until original sheet 10-08 is visually verified |
| TPT95-W-01 | TATPROF | TPT95 windows | P1 | web Rpr from 0.8 is summary, not proof for every configuration | project Rpr only from concrete composition calculation/test |
| TPT95-W-02 | TATPROF | TPT95 windows | P0 | max 2400x1700 and 180 kg are independent limits | never combine all maxima without profile/hardware check |
| TPT95-W-03 | TATPROF | TPT95 windows | P0 | catalog glazing matrix is discrete despite 44–58 mm range | select bead/seals row-by-row; no interpolation |
| TPT95-W-04 | TATPROF | TPT95 windows | P1 | static section cites historical SNiP | recalculate by current applicable standards |
| TPT95-W-05 | TATPROF | TPT95 windows | P2 | old catalog hardware list narrower than current web | store hardware as revision-specific configuration |
| TPT95-D-01 | TATPROF | TPT95 doors | P1 | web Rpr from 0.8 is summary | project value only for concrete tested/calculated assembly |
| TPT95-D-02 | TATPROF | TPT95 doors | P0 | web max 2500x1200; system sash mass not fixed in visible card | do not substitute hinge rating as system door mass |
| TPT95-D-03 | TATPROF | TPT95 doors | P0 | catalog shows hinges at 150/160/180 kg | treat as specific hinge/installation limits only |
| TPT95-D-04 | TATPROF | TPT95 doors | P1 | separate current door PDF and combined catalog are different source revisions | diff before merging; revision-tag every rule |
| TPT95-D-05 | TATPROF | TPT95 doors | P1 | historical static standards | use as source methodology, not current normative coefficients |
| FR-01 | TATPROF | TFS50FR | P0 | EI30 explicitly requires testing in catalog | do not mark EI30 as unconditional |
| FR-02 | TATPROF | TFS50FR | P0 | thermal tape side assignment conflicts between nomenclature and glazing tables | keep source tables separate; no automatic side correction |
| FR-03 | TATPROF | TFS50FR | P1 | F50.08.71 applicability differs between explanatory list and section 05 | use section-specific source; verify before order |
| FR-04 | TATPROF | TFS50FR | P1 | F50.08.74 applicability has 01/02 designation conflict | do not silently correct prefix |
| FR-05 | TATPROF | TFS50FR | P1 | type H F50.09.70 callout vs F50.08.73 table | not interchangeable until verified |
| FR-06 | TATPROF | TFS50FR | P1 | type F profile vs assembled designations not fully mapped | verify base catalog relationship |
| FR-07 | TATPROF | TFS50FR | P0 | hidden fire pressure element/structural fire glazing listed on request | no automatic serial specification |
| FR-08 | TATPROF | TFS50FR | P1 | reinforcement offset tables use identifiers inconsistent with .70–.72 reinforcement set | preserve literal labels; do not remap without proof |
| V72-01 | VIDNAL | V72 | P1 | 2026 technical table 25–56 mm vs web/description 25–49 mm | engineering selection follows concrete 2026 table/profile; store web value separately |
| V72-02 | VIDNAL | V72 | P1 | 2024 thermal value differs from 2026 card | never carry archive value into current card |
| V60-01 | VIDNAL | V60 | P0 | global infill range differs from profile tables, some profile reaches 52 mm | use profile/table-specific range only |
| V60-02 | VIDNAL | V60 | P0 | questionable horizontal bead formula through H in example | block automatic cutting formula until original sheet verified |
| V60-03 | VIDNAL | V60 | P0 | hinge/inter-axis values differ by source sheet | select hinge only from concrete mounting sheet and frame/sash profiles |
| V60L-01 | VIDNAL | V60L | P1 | official PDF indexed but bytes not in Library | selection okay; automatic spec requires tables 02/05/06 and processing geometry |
| V60L-02 | VIDNAL | V60L | P2 | system appears on architecture page/PDF but not main catalog navigation | treat as current; navigation omission is not discontinuation |
| V68-01 | VIDNAL | V68 | P0 | Roto size/mass maxima depend on opening/hardware/load-relief details | do not assume all maxima are simultaneously achievable |
| F50-01 | VIDNAL | F50 | P1 | historic example spreadsheets conflict with current full catalog | historical XLS only for example composition, never current system admission |
| F50-02 | VIDNAL | F50 RR | P0 | RR lacks normal transom-to-mullion condensate transfer and limited to <=2 floors vertical applications | separate drainage logic and mandatory insert angular displacement check |
| F50-03 | VIDNAL | F50 pSTR / STR | P0 | pseudo-structural mechanical solution and structural silicone solution are different systems | never mix pressure/clip/silicone logic across them |
| HS157-01 | VIDNAL | HS157 | P0 | 400 kg belongs to a specific Roto Patio Lift hardware/geometry group | not a universal sash limit |
| VP04-01 | VIDNAL | VP04 | P1 | SM/VP prefixes and profile captions ambiguous in source | no automatic aliasing |
| VP14-01 | VIDNAL | VP14 | P0 | pressure plate fastening step differs between description and processing sheet | block automated step selection until rule confirmed |
| VP14-02 | VIDNAL | VP14 | P0 | different corner connector designations for frame | verify current connector before procurement/autocomplete |
| V60EI-01 | VIDNAL | V60EI | P0 | official web claims EIW45/EIW60 but primary fire package not imported | no automatic fire specification without primary tested configuration documents |
| V60EI-02 | VIDNAL | V60EI | P0 | third-party certified products show EIS60/EI45/EIWS30/EIWS60, different scopes from VIDNAL positioning | treat every certificate as product-specific; never merge ratings into generic system capability |
| CERT-01 | VIDNAL | V60/V68/V72 | P1 | test protocols 75–83/2019 and 125/2019 are specimen-specific | do not generalize one specimen result to all configurations |
| F50-FIRE-01 | VIDNAL | F50 | P0 | E15 and 2024 inter-floor belt tests are different configurations/doc packages | fire rating only when project matches protocol/ATR/conclusion scope |
Универсальное правило
Ни одна запись с P0 не может быть автоматически превращена в «можно изготовить / соответствует». Все вычисления и спецификации должны сохранять source, revision/date, profile/node, application_scope, verification_status и ссылку на исходный лист/протокол. При конфликте источников система не выбирает удобное значение автоматически.
